|
ENVIRONMENTAL MICRODOSIMETRY IN VERY LOW DOSE RATE RADIATION FIELDS
Gabriele Auriemma, Anna Bianchi, Anna Selva, Valeria Conte
Pages: 28-33
DOI: 10.21175/RadProc.2023.06
Abstract |
References | Cite This | Full Text (PDF)
Low-dose radiation (LDR) has been demonstrated to have a significant impact on various immune
response mechanisms, potentially eliciting both stimulatory and adaptive reactions within living organisms. The
precise cellular mechanisms responsible for these radiation-induced immune responses warrant further in-depth
investigation. Within this context, the presence of research facilities both underground and at ground level at the Gran
Sasso Laboratories of the Italian National Institute of Nuclear Physics (INFN-LNGS) presents an excellent opportunity
for exploring the influence of low and extremely low doses of radiation in provoking immune responses. Conducting in
vitro and in vivo studies on the effects of LDR introduces several uncertainties, including the radiation quality, which
is often not closely monitored, and various uncontrolled physical variables. To address these challenges,
microdosimetric techniques will be employed to continuously monitor the absorbed dose and linear energy transfer
(LET) distribution of the environmental radiation field. This becomes particularly important at such low dose levels,
where the process of radiation interaction is primarily governed by stochastic effects, even for low LET radiation. To
facilitate this research, a large spherical tissue equivalent proportional counter (TEPC) with a diameter of 5 cm has
been designed at the Legnaro National Laboratories (LNL) of INFN. It is filled with propane gas to simulate a
thickness of 1-2 µm of biological tissue. This study presents and discusses microdosimetric spectra measured using the
aforementioned TEPC in various experimental scenarios.
- H. Planel, J.P. Soleilhavoup, R. Tixador, G. Richoilley,
A. Conter, F. Croute, C. Caratero, Y. Gaubin, “Influence
on cell proliferation of background radiation or
exposure to very low, chronic gamma radiation”,
Health Phys., 52(2), 571-8, 1987.
https://doi.org/10.1097/00004032-198705000-00007
- P. Morciano, F. Cipressa, A. Porrazzo, G. Esposito, M.A.
Tabocchini, G. Cenci, “Fruit Flies Provide New Insights
in Low-Radiation Background Biology at the INFN
Underground Gran Sasso National Laboratory
(LNGS)”, Radiat. Res., 190(3), 217-225. 2018.
https://doi.org/10.1667/RR15083.1
- A. Bettini, “Underground Laboratories”, J. Phys.: Conf.
Ser., 120, 082001, 2008.
https://doi.org/10.1088/1742-6596/120/8/082001
- Angelis, G. D'Imperio, V. Dini, C. Nuccetelli, M.C.
Quattrini, C. Tomei, A. Ianni, M. Balata, G. Carinci, M.
Chiti, O. Frasciello, G. Cenci, F. Cipressa, A. De
Gregorio, A. Porrazzo, M.A. Tabocchini, L. Satta, P.
Morciano, “Underground Radiobiology: A Perspective
at Gran Sasso National Laboratory”, Front. Public
Health, ,8, 2020.
https://doi.org/10.3389/fpubh.2020.611146
- N. Lampe, D.G. Biron, J.M.C. Brown, S. Incerti, P.
Marin, L. Maigne, D. Sarramia, H. Seznec, V. Breton,
“Simulating the Impact of the Natural Radiation
Background on Bacterial Systems: Implications for
Very Low Radiation Biological Experiments”, Plos One,
11(11), 2016.
https://doi.org/10.1371/journal.pone.0166364
- G. Baiocco, S. Bartzsch, V. Conte, T. Friedrich, B. Jakob,
A. Tartas, C. Villagrasa, K.M. Prise, “A matter of space:
how the spatial heterogeneity in energy deposition
determines the biological outcome of radiation
exposure.”, Radiat. Environ. Biophys., 61, 545–559,
2022.
https://doi.org/10.1007/s00411-022-00989-z
- International Commission on Radiation Units and
Measurements, “Microdosimetry Report 36.”,
Bethesda, MD, USA, 1983.
- D. Moro, L. De Nardo, P. Colautti, V. Conte2, T. Berger,
K. Marsalek, P. Beck, S. Rollet, M. Latocha, E. Bissiato,
G. Egeni, G. Donà, M. Luzik-Bhadra, A. Jaksi, M.
Vuotila, E. Koivula, G. Reitz, M. Dieckmann, U.
Straube, “EuTEPC - (European Tissue Equivalent
Proportional Counter): A microdosimeter for the
assessment of the radiation quality at the international
space station”, LNL-INFN Annual Report, p. 111, 2011.
https://www1.lnl.infn.it/~annrep/read_ar/2011/index
_contrib.htm
https://www1.lnl.infn.it/~annrep/read_ar/2011/contri
butions/pdfs/111_B_83_B078.pdf
- S. Chiriotti, D. Moro, P. Colautti, V. Conte, B.
Grosswendt, “Equivalence of pure propane and
propane te gases for microdosimetric measurements.”,
Radiat. Prot. Dosimetry., 166(1-4), 242-6, 2015.
https://doi.org/10.1093/rpd/ncv293
- A. Selva, L. Bellan, A. Bianchi, G. Giustiniani, P.
Colautti, E. Fagotti, A. Pisent, V. Conte,
“Microdosimetry of an accelerator based thermal
neutron field for boron neutron capture therapy.”,
Appl. Radiat. Isot., 182, 110144, 2022.
https://doi.org/10.1016/j.apradiso.2022.110144
- D. Moro, S. Chiriotti, V. Conte, P. Colautti, B.
Grosswendt, “Lineal calibration of a spherical TEPC”,
Radiat. Prot. Dosimetry, 166(1-4), 233–237, 2015.
https://doi.org/10.1093/rpd/ncv153
- A. Bianchi, A. Selva, P. Colautti, A. Parisi, F. Vanhavere,
B. Reniers, V. Conte, “The effect of different lower
detection thresholds in microdosimetric spectra and
their mean values”, Radiat. Meas., 146,, 106626, 2021.
https://doi.org/10.1016/j.radmeas.2021.10662
- Haiqian Ma, “Application of tissue equivalent
proportional counter (TEPC) in intercalibration with
nai(tl) spectrometer.” Master of Science in Particle
Physics at Carleton University, Ottawa, Ontario,
Canada, 2021.
- D. Moro, S. Chiriotti, “EuTEPC: measurements in
gamma and neutron fields”, Radiat. Prot.
Dosimetry, 166 (1-4), 266–270, 2015.
https://doi.org/10.1093/rpd/ncv154
Gabriele Auriemma, Anna Bianchi, Anna Selva, Valeria Conte, "Environmental microdosimetry in very low dose rate radiation fields", RAD Conf. Proc, vol. 7, 2023, pp. 28-33; http://doi.org/10.21175/RadProc.2023.06
|