Volume 7, 2023

Radiation Measurements

ENVIRONMENTAL MICRODOSIMETRY IN VERY LOW DOSE RATE RADIATION FIELDS

Gabriele Auriemma, Anna Bianchi, Anna Selva, Valeria Conte

Pages: 28-33

DOI: 10.21175/RadProc.2023.06

Low-dose radiation (LDR) has been demonstrated to have a significant impact on various immune response mechanisms, potentially eliciting both stimulatory and adaptive reactions within living organisms. The precise cellular mechanisms responsible for these radiation-induced immune responses warrant further in-depth investigation. Within this context, the presence of research facilities both underground and at ground level at the Gran Sasso Laboratories of the Italian National Institute of Nuclear Physics (INFN-LNGS) presents an excellent opportunity for exploring the influence of low and extremely low doses of radiation in provoking immune responses. Conducting in vitro and in vivo studies on the effects of LDR introduces several uncertainties, including the radiation quality, which is often not closely monitored, and various uncontrolled physical variables. To address these challenges, microdosimetric techniques will be employed to continuously monitor the absorbed dose and linear energy transfer (LET) distribution of the environmental radiation field. This becomes particularly important at such low dose levels, where the process of radiation interaction is primarily governed by stochastic effects, even for low LET radiation. To facilitate this research, a large spherical tissue equivalent proportional counter (TEPC) with a diameter of 5 cm has been designed at the Legnaro National Laboratories (LNL) of INFN. It is filled with propane gas to simulate a thickness of 1-2 µm of biological tissue. This study presents and discusses microdosimetric spectra measured using the aforementioned TEPC in various experimental scenarios.
  1. H. Planel, J.P. Soleilhavoup, R. Tixador, G. Richoilley, A. Conter, F. Croute, C. Caratero, Y. Gaubin, “Influence on cell proliferation of background radiation or exposure to very low, chronic gamma radiation”, Health Phys., 52(2), 571-8, 1987.
    https://doi.org/10.1097/00004032-198705000-00007
  2. P. Morciano, F. Cipressa, A. Porrazzo, G. Esposito, M.A. Tabocchini, G. Cenci, “Fruit Flies Provide New Insights in Low-Radiation Background Biology at the INFN Underground Gran Sasso National Laboratory (LNGS)”, Radiat. Res., 190(3), 217-225. 2018.
    https://doi.org/10.1667/RR15083.1
  3. A. Bettini, “Underground Laboratories”, J. Phys.: Conf. Ser., 120, 082001, 2008.
    https://doi.org/10.1088/1742-6596/120/8/082001
  4. Angelis, G. D'Imperio, V. Dini, C. Nuccetelli, M.C. Quattrini, C. Tomei, A. Ianni, M. Balata, G. Carinci, M. Chiti, O. Frasciello, G. Cenci, F. Cipressa, A. De Gregorio, A. Porrazzo, M.A. Tabocchini, L. Satta, P. Morciano, “Underground Radiobiology: A Perspective at Gran Sasso National Laboratory”, Front. Public Health, ,8, 2020.
    https://doi.org/10.3389/fpubh.2020.611146
  5. N. Lampe, D.G. Biron, J.M.C. Brown, S. Incerti, P. Marin, L. Maigne, D. Sarramia, H. Seznec, V. Breton, “Simulating the Impact of the Natural Radiation Background on Bacterial Systems: Implications for Very Low Radiation Biological Experiments”, Plos One, 11(11), 2016.
    https://doi.org/10.1371/journal.pone.0166364
  6. G. Baiocco, S. Bartzsch, V. Conte, T. Friedrich, B. Jakob, A. Tartas, C. Villagrasa, K.M. Prise, “A matter of space: how the spatial heterogeneity in energy deposition determines the biological outcome of radiation exposure.”, Radiat. Environ. Biophys., 61, 545–559, 2022.
    https://doi.org/10.1007/s00411-022-00989-z
  7. International Commission on Radiation Units and Measurements, “Microdosimetry Report 36.”, Bethesda, MD, USA, 1983.
  8. D. Moro, L. De Nardo, P. Colautti, V. Conte2, T. Berger, K. Marsalek, P. Beck, S. Rollet, M. Latocha, E. Bissiato, G. Egeni, G. Donà, M. Luzik-Bhadra, A. Jaksi, M. Vuotila, E. Koivula, G. Reitz, M. Dieckmann, U. Straube, “EuTEPC - (European Tissue Equivalent Proportional Counter): A microdosimeter for the assessment of the radiation quality at the international space station”, LNL-INFN Annual Report, p. 111, 2011.https://www1.lnl.infn.it/~annrep/read_ar/2011/index _contrib.htm
    https://www1.lnl.infn.it/~annrep/read_ar/2011/contri butions/pdfs/111_B_83_B078.pdf
  9. S. Chiriotti, D. Moro, P. Colautti, V. Conte, B. Grosswendt, “Equivalence of pure propane and propane te gases for microdosimetric measurements.”, Radiat. Prot. Dosimetry., 166(1-4), 242-6, 2015.
    https://doi.org/10.1093/rpd/ncv293
  10. A. Selva, L. Bellan, A. Bianchi, G. Giustiniani, P. Colautti, E. Fagotti, A. Pisent, V. Conte, “Microdosimetry of an accelerator based thermal neutron field for boron neutron capture therapy.”, Appl. Radiat. Isot., 182, 110144, 2022.
    https://doi.org/10.1016/j.apradiso.2022.110144
  11. D. Moro, S. Chiriotti, V. Conte, P. Colautti, B. Grosswendt, “Lineal calibration of a spherical TEPC”, Radiat. Prot. Dosimetry, 166(1-4), 233–237, 2015.
    https://doi.org/10.1093/rpd/ncv153
  12. A. Bianchi, A. Selva, P. Colautti, A. Parisi, F. Vanhavere, B. Reniers, V. Conte, “The effect of different lower detection thresholds in microdosimetric spectra and their mean values”, Radiat. Meas., 146,, 106626, 2021.
    https://doi.org/10.1016/j.radmeas.2021.10662
  13. Haiqian Ma, “Application of tissue equivalent proportional counter (TEPC) in intercalibration with nai(tl) spectrometer.” Master of Science in Particle Physics at Carleton University, Ottawa, Ontario, Canada, 2021.
  14. D. Moro, S. Chiriotti, “EuTEPC: measurements in gamma and neutron fields”, Radiat. Prot. Dosimetry, 166 (1-4), 266–270, 2015.
    https://doi.org/10.1093/rpd/ncv154