Clinical studies have shown that it is possible to improve image contrast up to 30% when time of flight (TOF) technology is used compared to non­TOF technology [1]. On the other hand, it has been shown that, combined with the point spread function (PSF) information and current ordered-subset-maximum-likelihood (OSEM) algorithm, image quality for overweight patients could be significantly improved by applying TOF. This encourages further study and a change of the dose model based on patient weight. This change would result in the revision of the existing EANM procedure guidelines, either replacing them or combining them with a system based on a body­mass­index (BMI) concept, and thus result in significant dose reductions with stronger patient­based dose optimisation. This will also reduce exposure of the nuclear medicine staff. Bearing in mind that the compromise in clinical practice is either to reduce the time of the scan or to reduce the patient dose, and that this depends mostly on whether a facility has a medical cyclotron or not, this work focuses on the overview of possibilities for potential reduction of patient dose based on appropriate clinical studies.
  1. S. Surti, “Update on Time­of­Flight PET Imaging,” J. Nucl. Med., vol. 56, no. 1, pp. 98–105, Jan. 2015
    DOI: 10.2967/jnumed.114.145029
  2. J. Qi, R.M. Leahy, S.R. Cherry, A. Chatziioannou and T.H. Farquhar, “High-Resolution 3D Bayesian Image Reconstruction Using the MicroPET Small-Animal Scanner,” Phys. Med. Biol., vol. 43, no. 4, pp. 1001-1013, 1998
    DOI: 10.1088/0031-9155/43/4/027
  3. R. Boellaard et al., “FDG PET and PET/CT: EANM Procedure Guidelines for Tumour Imaging: Version 2.0,” Eur. J. Nucl. Med. Mol. Imag., vol. 37, pp. 328-354, Feb. 2015
    DOI: 10.1007/s00259-014-2961-x
  4. M.H. Mahmud, A.J. Nordin, F.F. Ahmad Saad, A.Z. Azman, “Impacts of Biological and Procedural Factors on Semiquantification Uptake Value of Liver in Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Imaging,” Quant. Imag. Med. Surg., vol. 5, no. 5, pp. 700-707, Oct. 2015
    DOI: 10.3978/j.issn.2223-4292.2015.05.02
  5. R. Boellaard, A.T. Willemsen, B. Arends, E.P. Visser, “EARL Procedure for Assessing PET/CT System Specific Patient FDG Activity Preparations for Quantitative FDG PET/CT Studies”
    Retrieved from: http://earl.eanm.org/html/img/pool/EARL­procedure­for­optimizing­FDG­activity­for­quantiative­FDGPET­studies_version_1_1.pdf
    Retrieved on: Feb. 20, 2016
  6. R. Sanchez-Jurado, M. Devis, R. Sanz, J. E. Aguilar, M. del Puig Cózar and J. Ferrer-Rebolleda, “Whole­Body PET/CT Studies with Lowered 18F­FDG Doses: The Influence of Body Mass Index in Dose Reduction,” J. Nucl. Med. Technol., vol. 42, no. 1, pp. 62–67, Mar. 2014
    DOI: 10.2967/jnmt.113.130393
  7. Y.S. Lee, J.S. Kim, K.M. Kim, J.H. Kang, S.M. Lim, H.-J. Kim, “Performance Measurement of PSF Modeling Reconstruction (True X) on Siemens Biograph TruePoint TrueV PET/CT,” Ann. Nucl. Med., vol. 28, no.4, pp. 340-348, May 2014
    DOI: 10.1007/s12149-014-0815-z
  8. S. Sheikhbahaei, C. Marcus, R. Wray, A. Rahmim, M.A. Lodge and R.M. Subramaniam, “Impact of Point Spread Function Reconstruction on Quantitative 18F-FDG-PET/CT Imaging Parameters and Inter-Reader Rreproducibility in Solid tumors,” Nucl. Med. Commun., vol. 37, no. 3, pp. 288-296, Mar. 2016
  9. T. Taniguchi et al. “Improvement in PET/CT Image Quality in Overweight Patients with PSF and TOF,” Ann. Nucl. Med., vol. 29, no. 1, pp. 71–77, Jan. 2015
    DOI: 10.1007/s12149-014-0912-z
  10. I.S. Armstrong, M.D. Kelly, H.A. Williams and J.C. Matthews, “Impact of Point Spread Function Modelling and Time of Flight on FDG Uptake Measurements in Lung Lesions Using Alternative Filtering Strategies,” EJNMMI Phys., vol. 1, no. 1, p. 99, Dec. 2014
    DOI: 10.1186/s40658-014-0099-3
  11. J.H. Geismar et al., “Intra­Individual Comparison of PET/CT with Different Body Weight­Adapted FDG Dosage Regimens,” Acta Radiol. Open, vol. 4, no. 2, pp. 1-9, Feb. 2015
    DOI: 10.1177/2047981614560076
  12. G. Akamatsu et al., “Improvement in PET/CT Image Quality with a Combination of Point­Spread Function and Time­of­Flight in Relation to Reconstruction Parameters,” J. Nucl. Med., vol. 53, no. 11, pp. 1716-1722, Nov. 2012
    DOI: 10.2967/jnumed.112.103861
  13. J. Schaefferkoetter, M. Casey, D. Townsend and G. El Fakhri, “Clinical Impact of Time­of­Flight and Point Response Modeling in PET Reconstructions: A Lesion Detection Study,” Phys. Med. Biol., vol. 58, no. 5, pp. 1465-1478, Mar. 2013
    DOI: 10.1088/0031-9155/58/5/1465
  14. Y. Masuda, C. Kondo, Y. Matsuo, M. Uetani and K. Kusakabe, “Comparison of Imaging Protocols for 18F-­FDG PET/CT in Overweight Patients: Optimizing Scan Duration Versus Administered Dose,” J. Nucl. Med., vol. 50, no. 6, pp. 844-848, June 2009
    DOI: 10.2967/jnumed.108.060590