NEED FOR REVISING PATIENT DOSE PROTOCOLS IN PET MEDICAL IMAGING BASED ON NOVEL TECHNOLOGY IMPROVEMENTS
Vojislav Antic, Julie Haglund
Pages: 124-126
DOI: 10.21175/RadProc.2016.29
Abstract |
References | Full Text (PDF)
Clinical studies have shown that it is possible to improve image contrast up to 30% when time of flight (TOF) technology is used compared to nonTOF technology [1]. On the other hand, it has been shown that, combined with the point spread function (PSF) information and current ordered-subset-maximum-likelihood (OSEM) algorithm, image quality for overweight patients could be significantly improved by applying TOF. This encourages further study and a change of the dose model based on patient weight. This change would result in the revision of the existing EANM procedure guidelines, either replacing them or combining them with a system based on a bodymassindex (BMI) concept, and thus result in significant dose reductions with stronger patientbased dose optimisation. This will also reduce exposure of the nuclear medicine staff. Bearing in mind that the compromise in clinical practice is either to reduce the time of the scan or to reduce the patient dose, and that this depends mostly on whether a facility has a medical cyclotron or not, this work focuses on the overview of possibilities for potential reduction of patient dose based on appropriate clinical studies.
- S. Surti, “Update on TimeofFlight PET Imaging,” J. Nucl. Med., vol. 56, no. 1, pp. 98–105, Jan. 2015
DOI: 10.2967/jnumed.114.145029
- J. Qi, R.M. Leahy, S.R. Cherry, A. Chatziioannou and T.H. Farquhar, “High-Resolution 3D Bayesian Image Reconstruction Using the MicroPET Small-Animal Scanner,” Phys. Med. Biol., vol. 43, no. 4, pp. 1001-1013, 1998
DOI: 10.1088/0031-9155/43/4/027
- R. Boellaard et al., “FDG PET and PET/CT: EANM Procedure Guidelines for Tumour Imaging: Version 2.0,” Eur. J. Nucl. Med. Mol. Imag., vol. 37, pp. 328-354, Feb. 2015
DOI: 10.1007/s00259-014-2961-x
- M.H. Mahmud, A.J. Nordin, F.F. Ahmad Saad, A.Z. Azman, “Impacts of Biological and Procedural Factors on Semiquantification Uptake Value of Liver in Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Imaging,” Quant. Imag. Med. Surg., vol. 5, no. 5, pp. 700-707, Oct. 2015
DOI: 10.3978/j.issn.2223-4292.2015.05.02
- R. Boellaard, A.T. Willemsen, B. Arends, E.P. Visser, “EARL Procedure for Assessing PET/CT System Specific Patient FDG Activity Preparations for Quantitative FDG PET/CT Studies”
Retrieved from: http://earl.eanm.org/html/img/pool/EARLprocedureforoptimizingFDGactivityforquantiativeFDGPETstudies_version_1_1.pdf
Retrieved on: Feb. 20, 2016
- R. Sanchez-Jurado, M. Devis, R. Sanz, J. E. Aguilar, M. del Puig Cózar and J. Ferrer-Rebolleda, “WholeBody PET/CT Studies with Lowered 18FFDG Doses: The Influence of Body Mass Index in Dose Reduction,” J. Nucl. Med. Technol., vol. 42, no. 1, pp. 62–67, Mar. 2014
DOI: 10.2967/jnmt.113.130393
- Y.S. Lee, J.S. Kim, K.M. Kim, J.H. Kang, S.M. Lim, H.-J. Kim, “Performance Measurement of PSF Modeling Reconstruction (True X) on Siemens Biograph TruePoint TrueV PET/CT,” Ann. Nucl. Med., vol. 28, no.4, pp. 340-348, May 2014
DOI: 10.1007/s12149-014-0815-z
- S. Sheikhbahaei, C. Marcus, R. Wray, A. Rahmim, M.A. Lodge and R.M. Subramaniam, “Impact of Point Spread Function Reconstruction on Quantitative 18F-FDG-PET/CT Imaging Parameters and Inter-Reader Rreproducibility in Solid tumors,” Nucl. Med. Commun., vol. 37, no. 3, pp. 288-296, Mar. 2016
- T. Taniguchi et al. “Improvement in PET/CT Image Quality in Overweight Patients with PSF and TOF,” Ann. Nucl. Med., vol. 29, no. 1, pp. 71–77, Jan. 2015
DOI: 10.1007/s12149-014-0912-z
- I.S. Armstrong, M.D. Kelly, H.A. Williams and J.C. Matthews, “Impact of Point Spread Function Modelling and Time of Flight on FDG Uptake Measurements in Lung Lesions Using Alternative Filtering Strategies,” EJNMMI Phys., vol. 1, no. 1, p. 99, Dec. 2014
DOI: 10.1186/s40658-014-0099-3
- J.H. Geismar et al., “IntraIndividual Comparison of PET/CT with Different Body WeightAdapted FDG Dosage Regimens,” Acta Radiol. Open, vol. 4, no. 2, pp. 1-9, Feb. 2015
DOI: 10.1177/2047981614560076
- G. Akamatsu et al., “Improvement in PET/CT Image Quality with a Combination of PointSpread Function and TimeofFlight in Relation to Reconstruction Parameters,” J. Nucl. Med., vol. 53, no. 11, pp. 1716-1722, Nov. 2012
DOI: 10.2967/jnumed.112.103861
- J. Schaefferkoetter, M. Casey, D. Townsend and G. El Fakhri, “Clinical Impact of TimeofFlight and Point Response Modeling in PET Reconstructions: A Lesion Detection Study,” Phys. Med. Biol., vol. 58, no. 5, pp. 1465-1478, Mar. 2013
DOI: 10.1088/0031-9155/58/5/1465
- Y. Masuda, C. Kondo, Y. Matsuo, M. Uetani and K. Kusakabe, “Comparison of Imaging Protocols for 18F-FDG PET/CT in Overweight Patients: Optimizing Scan Duration Versus Administered Dose,” J. Nucl. Med., vol. 50, no. 6, pp. 844-848, June 2009
DOI: 10.2967/jnumed.108.060590
|