|
EXPERIMENTAL MEASUREMENT OF SECONDARY NEUTRONS ON PARTICLE ACCELERATORS
Aleš Jančář, Zdeněk Kopecký, Jiří Čuleň, Filip Mravec, Zdeněk Matěj
Pages: 26–30
DOI: 10.21175/RadProc.2022.05
Abstract |
References | Cite This | Full Text (PDF)
A newly developed fast digital spectrometer for neutron spectroscopy is presented. The pulse shape discrimination (PSD) performance of the spectrometer has been evaluated within two experiments with different neutron energies. The experimental measurements of secondary neutrons were carried out in the laboratory of the Van de Graaff accelerator and at the Proton Therapy Center in Prague. For both experiments, a liquid scintillator detector BC-501A (NE-213) was used. The results of experiments demonstrate the very good quality of the PSD discrimination of the spectrometer. The experimental spectra of secondary neutrons were compared with spectra obtained by means Monte Carlo simulations. The detector response matrix and the flux of secondary neutrons and protons in the vicinity of irradiated proton therapy phantom were calculated using Monte Carlo simulations.
-
A. Jančář et al., “Pulse-shape discrimination of the new plastic scintillators in neutron–gamma mixed field using fast digitizer card,” Radiation Physics and Chemistry, vol. 116, pp. 60–64, Nov.2015.
DOI:
10.1016/j.radphyschem.2015.05.007
-
F. D. Brooks, “A scintillation counter with neutron and gamma-ray
discriminators,” Nucl. Instr. Meth., vol. 4, no. 3, pp.
151–163, Apr. 1959.
DOI:
10.1016/0029-554X(59)90067-9
-
R. A. Winyard, J. E. Lutkin, G. W. McBeth, “Pulse shape discrimination
in inorganic and organic scintillators. I,” Nucl. Instr. Meth., vol. 95, no. 1, pp. 141–153, Aug. 1971.
DOI:
10.1016/0029-554X(71)90054-1
-
Z. Matěj at al., “Digital two-parametric processing of the output data
from radiation detectors,” Prog. Nucl. Sci. Tech., vol. 4, pp.
670–674, Sep. 2014.
DOI:
10.15669/pnst.4.670
-
G. Dietze, H. Klein, “Gamma-calibration of NE 213 scintillation
counters,” Nucl. Instr. Meth. Phys. Res., vol. 193, no. 3, pp.
549–556, Mar. 1982.
DOI:
10.1016/0029-554X(82)90249-X
-
N. Nakao et al., “Measurements of response function of organic liquid scintillator for neutron energy range up to 135 MeV,” Nucl. Instr. Meth. Phys. Res. A, vol. 362, no. 2–3, pp.
454–465, Aug. 1995.
DOI:
10.1016/0168-9002(95)00193-X
-
C. J. Werner et al., MCNP Version 6.2 Release Notes, Technical
Report LA-UR-18-20808, Los Alamos National Laboratory, Los Alamos (NM),
USA, 2018.
DOI:
10.2172/1419730
-
C. J. Werner, Ed., MCNP® User’s Manual, Technical
Report LA-UR-17-29981, Los Alamos National Laboratory, Los Alamos (NM),
USA, 2017.
Retrieved from:
https://mcnp.lanl.gov/pdf_files/TechReport_2017_LANL_LA-UR-17-29981_WernerArmstrongEtAl.pdf
Retrieved on: Jun. 15, 2022
Aleš Jančář, Zdeněk Kopecký, Jiří Čuleň, Filip Mravec, Zdeněk Matěj, "Experimental measurement of secondary neutrons on particle accelerators", RAD Conf. Proc, vol. 6, 2022, pp. 26–30, http://doi.org/10.21175/RadProc.2022.05
|