MAMMOGRAPHY IN SERBIA: IMAGE QUALITY AND RADIATION DOSE
Stefan Rafajlovic, Danijela Arandjic, Predrag Bozovic, Sandra Ceklic, Djordje Lazarevic, Olivera Ciraj-Bjelac
Pages: 29-32
DOI: 10.21175/RadProc.2016.08
Abstract |
References | Full Text (PDF)
The purpose of this study is to investigate the radiation dose and technical image quality in mammography in Serbia after two years of implementation of the breast screening programme. A total of 186 mammography units, including Full-Field Digital Mammography (FFDM), Computed Radiography (CR) and Screen-Film Mammography (SFM) units were used in the patient dose and image quality assessment. Patient dose, in terms of Mean Glandular Dose (MGD), was assessed for the standard breast, while image quality was evaluated in terms of spatial resolution, threshold contrast visibility and Contrast to Noise Ratio (CNR) for CR and FFDM units. The mean MGD assessed was (1.8±0.94) mGy, (1.3±0.51) and (1.7±0.64) for CR, FFDM and SFM, respectively. Spatial resolution was better than 12 lp/mm only for 3/186 (1.6%) units. In 34/186 (18%) units, spatial resolution was less than 5 lp/mm. Threshold contrast visibility was better than 1.2 in 41/186 (22%). Mean CNR for CR and FFDM units was 5.2 ±2.2. Following the initial implementation at the beginning of the population-based breast cancer screening campaign, it is essential to establish an effective system of regular and periodic Quality Control (QC) tests and to ensure that high-quality mammograms with minimal possible radiation dose to population are included in the screening.
- O. Ciraj-Bjelac, D. Faj, D. Stimac, D. Kosutic, D. Arandjic and H. Brkic, “Good Reasons to Implement Quality Assurance in Nationwide Breast Cancer Screening Programs in Croatia and Serbia: Results from a Pilot Study,” Eur. J. Radiol., vol. 78, no. 1, pp. 122-128, Apr. 2011
DOI: 10.1016/j.ejrad.2009.10.004
- European Commission. (2006). European guidelines for quality assurance in breast cancer screening and diagnosis, 4th ed.
- R.E. Hendric et al., Mammography Quality Control: Radiologist's Manual, Radiological Technologist's Manual, Medical Physicist's Manual, 4th ed., Reston (VA), USA: American College of Radiology, 1999
- “The Commissioning and Routine Testing of Mammographic X-Ray Systems,” IPEM, York, UK, Rep. 89, 2005
- O. Ciraj-Bjelac et al., “Image Quality and Dose in Mammography in 17 Countries in Africa, Asia and Eastern Europe: Results from IAEA Project,” Eur. J. Radiol., vol. 81, no. 9, pp. 2161-2168, Sep. 2012
DOI: 10.1016/j.ejrad.2011.05.026
- P. Mora et al., “Latin American Image Quality Survey in Digital Mammography Studies,” Rad. Prot. Dosim., Mar. 2016
DOI: 10.1093/rpd/ncw049
- O. Ciraj-Bjelac, P. Bozovic, Dj. Lazarevic, D. Arandjic, D. Kosutic, “Quality Control for the Mammography Screening Program in Serbia Physical and Technical Aspects,” in Proceed. Eur. Med. Phys. Eng. Conf., Sofia, Bulgaria, 18-20 Oct. 2012, pp.231-236
- “Dosimetry in Diagnostic Radiology: An International Code of Practice,” IAEA, Vienna, Austria, Tech. rep. ser. no. 457, 2007
- J. Nederend et al., “Impact of the Transition from Screen-Film to Digital Screening Mammography on Interval Cancer Characteristics and Treatment – A Population Based Study from the Netherlands,” Eur. J. Canc., vol. 50, no. 1, pp. 31–39, Jan. 2014
DOI: 10.1016/j.ejca.2013.09.018
- L. Timmermans et al., “Impact of the Digitalisation of Mammography on Performance Parameters and Breast Dose in the Flemish Breast Cancer Screening Programme,” Eur. Radiol., vol. 24, no. 8, pp. 1808-1819, Aug. 2014
DOI: 10.1007/s00330-014-3169-y
- A. Mackenzie et al., “Breast Cancer Detection Rates Using Four Different Types of Mammography Detectors,” Eur. Radiol., vol. 26, no. 3, pp. 874-883, Mar. 2016
DOI: 10.1007/s00330-015-3885-y
- D. O'Leary and L. Rainford, “A Comparison of Mean Glandular Dose Diagnostic Reference Levels within the All-Digital Irish National Breast Screening Programme and the Irish Symptomatic Breast Services,” Rad. Prot. Dosim., vol. 153, no. 3, pp. 300-308, Mar. 2013
DOI: 10.1093/rpd/ncs112
- M.J. Yaffe et al., “Comparative Performance of Modern Digital Mammography Systems in a Large Breast Screening Program,” Med. Phys., vol. 40, no. 12, pp. 121915 (1-10), Dec. 2013
DOI: 10.1118/1.4829516
|